Colocation contract terms to negotiate before you sign
The colocation contract terms that decide what you pay over the years and how easily you can leave are mostly set in the provider's first draft of the colocation agreement: term length, power pricing and escalators, renewal, expansion rights, SLA credits and their limits, cross-connect and remote hands rates, early termination, assignment, and liability and insurance. Those are the twelve terms below, each with what to watch in the draft and what to ask for.
This page is general information for buyers, not legal advice. Your counsel confirms the final language.
The twelve colocation agreement terms at a glance
| Term | What to watch in the first draft | What to ask for |
|---|---|---|
| Term length | A long commitment priced as the only option | Pricing for at least two term lengths, so the trade is visible |
| Power pricing | A rate per circuit or per kWh with no basis for later changes | The billing model in writing, and any pass-through tied to the actual utility tariff with documents |
| Escalators | Annual increases tied to an index plus a margin, or uncapped | A fixed annual cap for the term |
| Renewal | Automatic renewal for the same length, with a short notice window | Renewal at your option, a cap on the renewal increase, and a notice window long enough to run a new search |
| Expansion rights | No reserved space, or space held for a short time only | A right of first refusal on adjacent space, with expansion priced at your current rates |
| SLA scope | Credits for power only, or credits that end above a set circuit load | Power, cooling, network if bought, and remote hands response, each defined |
| SLA credits and limits | Credits capped at the affected service's monthly fee, short claim windows | A longer claim window, automatic credits from monitoring, and a right to exit after repeated failures |
| Cross-connect fees | "Per current rate card" | The one-time and monthly fee per cross-connect type, fixed or capped for the term |
| Remote hands rates | Hourly rates and minimums not in the contract | The rate card attached, with billing increment, after-hours rate and included tasks |
| Early termination | All remaining fees due at once | Termination rights for chronic SLA failure and missed ready-for-service dates, and a defined fee otherwise |
| Assignment | Transfer blocked without consent, including through a merger | Assignment to affiliates and successors in a merger or sale without needing consent |
| Liability and insurance | Liability capped at a few months of fees, your insurance requirements set high | Carve-outs from the cap agreed with counsel, and insurance limits your risk team confirms |
Term length and renewal
Providers often ask for multi-year commitments, and terms sometimes run up to a decade, according to a May 2026 review of colocation agreements by the law firm Morgan Lewis. A longer term can buy a lower rate, but only if the renewal terms don't take the saving back.
Check the renewal clause line by line. Atlantic.Net's published colocation agreement, as one example, renews automatically for a term equal to the first one unless either side cancels in writing at least 30 days before it ends. Thirty days is not enough time to run a new provider search, so a missed date locks in another full term.
Ask for: renewal at your option, a cap on any increase at renewal, and a notice window that starts early enough to run a selection. Put the notice deadline in your contract calendar on the day you sign.
Power pricing and escalators
Power is usually the largest line, and it can be billed two ways: per circuit reserved, whether you use it or not, or per kWh measured. Ask which, and how the rate can change. Morgan Lewis notes that annual escalators may be fixed or tied to an index.
Read the price change clause for more than one lever. Atlantic.Net's agreement allows increases in line with regional CPI plus 2% after the first twelve months, and separately in proportion to regional electricity cost increases at any time. Market pressure points the same way: in its H1 2026 report, CBRE said average asking rates rose in every size tier, from 4.3% for 250 to 500 kW requirements up to 8.3% for 3 to 10 MW.
Ask for: a fixed annual cap on the escalator, any power pass-through tied to the actual utility tariff with documents, and the right to see the meter data behind any metered bill.
Expansion rights and right of first refusal
Growth room is easiest to secure before you sign. Morgan Lewis lists the ability to add or reduce power and space, and rights to adjacent capacity, among the points to cover.
Ask for: a right of first refusal on named adjacent space, a reservation period that matches your growth plan, expansion priced at your current rates, and the ability to add power to existing cabinets up to a stated limit.
Colocation SLA: what the credits cover and where they stop
A colocation SLA can cover power, cooling, network and response times. The first questions are what is covered, how an outage is defined, and what you must do to claim.
Published agreements show where the limits usually sit. In Atlantic.Net's colocation agreement:
- A power outage earns one hour of the affected circuit's monthly fee for each 15 minutes of downtime, capped at 100% of that circuit's monthly fee.
- You must open a ticket within one business day and send written notice within ten calendar days.
- Credits don't apply when continuous load exceeds 80% of the breaker's rating.
- Fees keep running while the claim is reviewed.
Credits are a small share of what an outage costs a business, so treat them as a signal of how the provider measures itself, not as protection.
Ask for: each covered service defined, credits applied automatically from the provider's own monitoring, a longer claim window, and a right to terminate without penalty after repeated failures in a set period.
Check the SLA scope against our checklist's power items.
Cross-connect and remote hands fees
These are small per item and add up over a term. Morgan Lewis flags that cross-connect fees can add up over time.
Remote hands rates vary widely by provider. Two published rate sheets as examples:
| Rate sheet | Business hours | Off hours | Billing increment |
|---|---|---|---|
| STACK Infrastructure, effective June 1, 2025 | $250 an hour | $375 an hour | 15 minutes |
| 365 Data Centers, no service plan | $165 an hour | $165 an hour, two-hour minimum | 30 minutes |
Some providers include basic tasks and quote advanced work separately, so the hourly rate is only part of the comparison.
Ask for: the cross-connect price per type, fixed or capped for the term; the remote hands rate card attached to the contract; the list of included tasks; and any bundled hours priced in writing.
Early termination, removal and holdover
Read the exit terms as closely as the price. In Atlantic.Net's agreement, leaving early for any reason other than the provider's default makes all fees for the full term due within ten days, and equipment must be removed promptly after the end of the agreement. Morgan Lewis lists removal timelines, data destruction duties and holdover fees among the exit points to settle.
Ask for: termination rights for chronic SLA failure and for a missed ready-for-service date, a removal window long enough for an orderly migration, a stated holdover rate, and a defined early termination fee in place of full acceleration.
Assignment and change of control
If your company is bought, sold or reorganized, the colocation contract has to move with it. Atlantic.Net's agreement treats the license as personal to the customer and requires the provider's consent for any transfer, including through a merger or sale of control, at the provider's sole discretion.
Ask for: the right to assign to affiliates and to a successor in a merger or sale without consent, with notice to the provider.
Liability caps, insurance and indemnity
Providers usually cap their liability and exclude indirect losses. Morgan Lewis names liability caps, SLA credits and ready-for-service remedies among the most negotiated provisions. As one example, Atlantic.Net caps its total liability at the fees paid in the three months before the event.
The contract also sets insurance you must carry. Atlantic.Net's agreement requires $1,000,000 per occurrence of commercial general liability, property cover at full replacement cost and the provider named as an additional insured, among other items.
Ask for: carve-outs from the cap agreed with your counsel, a mutual approach to indemnity, and insurance limits your risk team confirms you already carry.
Colocation contract negotiation: when you have leverage
- Before the provider knows it has won. Keep two providers in the process until terms are agreed.
- When you can trade. A longer term, a larger first phase or a partial prepayment can be traded for a capped escalator, fixed cross-connect pricing or expansion rights. TechTarget's guide to colocation negotiation lists prepayment as one such trade.
- When the provider has space to fill. Providers with unused capacity in a building tend to be more flexible.
- Before your current contract's notice date. Once that date passes, your current provider knows you have to stay or move fast.
Track every term in one place
The term tracker lists the twelve terms with what to ask for, and blank columns for the provider's first draft, your counter, the status and the owner. Procurement keeps it, counsel reviews it, and nothing is signed while a row says "Open".
Questions about colocation contracts
What is a colocation agreement?
It is usually a master services agreement plus order forms for each site, a service level agreement, and policies such as access rules and acceptable use. The order form holds the prices and quantities, so read it as closely as the master agreement.
Are colocation contract terms negotiable?
Many are, especially on enterprise deals. Your leverage comes from the size and length of the commitment, a second provider still in the process, and timing. Some providers keep fixed rates for small deployments, so ask early which items are open.
What annual escalator should we expect?
It varies. Escalators can be a fixed percentage or tied to an index, sometimes with a margin on top and a separate power pass-through. Ask for a fixed cap for the term and compare the cap, not the first year's price.
Do SLA credits cover our losses from an outage?
Rarely. Credits are usually capped at a share of the affected service's monthly fee, and liability for indirect losses is usually excluded. The SLA tells you how the provider measures itself. Your own redundancy is what protects the business.
When should we start renegotiating a renewal?
Well before the notice deadline in your current contract. If the window is short, you may have little time to run a real alternative, which is when the renewal price is hardest to move.
Is this page legal advice?